| dc.contributor.author | D. R. Holder | en_US |
| dc.date.accessioned | 2014-10-21T15:55:52Z | |
| dc.date.available | 2014-10-21T15:55:52Z | |
| dc.date.issued | 1962 | en_US |
| dc.identifier.other | ARC/R&M-3322 | en_US |
| dc.identifier.uri | https://reports.aerade.cranfield.ac.uk/handle/1826.2/3902 | |
| dc.description.abstract | Solutions have been obtained for the upwash interference on two-dimensional aerofoils, and small-span wings, in a rectangular wind tunnel with viscous flow through the slotted floor and roof. A discussion is included on the application of results to tests on wings of moderate span. | en_US |
| dc.relation.ispartofseries | Aeronautical Research Council Reports & Memoranda | en_US |
| dc.title | Upwash interference in a rectangular wind tunnel with closed side walls and porous slotted floor and roof | en_US |