Abstract:
This report describes tests carried out on tile 30 per cent Griffith symmetricM aerofoil with continuous suction applied through a porous capping fitted over tile front 15 per cent of the upper surface. Throughout the range of incidence covered in the experiments, distributed suction was found to decrease the slot suction necessary to prevent separation, especially when the distributed suction caused rearward movement of the transition position. The profile drag of the aerofoil was measured, and estimates were made of the equivalent drag coefficients for the work done by the suction pumps. Assuming no losses additional to those in the boundary layer, it was found that the effect of distributed suction was to reduce slightly the overall drag of the aerofoil. Measurements of the velocity within the boundary layer were made at various chordwise positions on the porous surface; the profiles recorded were very close to the theoretical. Distributed suction was able to delay transition when this would otherwise be precipitated by a ridge on the surface, or by adverse pressure gradients, but a turbulent boundary layer remained turbulent when suction was applied. The characteristic spread of turbulent flow in the wake of a small particle on the surface was much reduced by distributed suction; under favourable conditions, the wake was entirely eliminated.